3 Phase Isolating Transformer / Vertical mounting versionDTS 2.0 - 5.0kVA according to IEC/DIN EN61558-2-4

overviewtechnical dataPDF data sheet

Typical applications

3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).

Specifications

3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.

Any switching matrix can be realized. Standard switching matrix: Yyn0 (max. typical star load of phase current: approx. 10%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage).

Final operation position must allow natural convection through coolant bores. For further information, don´t hesitate to contact us.

Transformer provides 2 loops for safe transportation or craning (core sizes > 3UI150/65 – 4.5 kVA).

 

3 phase isolating transformer according to IEC/EN61558-2-4

natural convection through coolant bores

Voltage range / Input, Output 200 V … 550 V
Rated frequency 50/60 Hz
Power range 2,0kVA … 5,0kVA
Max. ambient temperature 40°C
UL-Insulation system (optional) OBJY2.E181051
Insulation class (IEC85) B 130°C
Fire protection class UL94HB (V-0 möglich)
Open transformer – degree of protection IP00
Protection class (ready) I
  • Transformer completely vacuum impregnated
  • Standard switching matrix Yyn0 (typical star load approx. 10%)
  • Screw terminals contact proof according to VBG4
  • Ready for vertical mounting – including angle brackets
Rated
power
kVA
Dimensions
approx. mm
Copper
weight
KG


Total
weight
KG


Size Type
A
B
C
D
E
F
2,0
245
130
207
185
81
9,0×13,0
6,30
19,30
3UI 120/51
DTS0200
2,5 265 130
227
200
76
10,0×18,0
7,50 20,50 3UI 132/46 DTS0250
3,2 265 145
227
200
90
10,0×18,0
8,20 25,50 3UI 132/60 DTS0320
4,0
300 150
260
224
94
10,0×18,0
12,20 31,80 3UI 150/52 DTS0400
4,5*
300 165
260
224
107
10,0×18,0
11,40
36,50
3UI 150/65 DTS0450
5,0*
335 155
290
248
110
10,0×18,0
17,00
44,00 3UI 168/58 DTS0500

Please note

* Version with lifting brackets for transportation.

3 Phase Isolating Transformers Circuits and Circuit Designs

3 phase isolation transformers offer various possibilities to connect PRIMARY and SECUNDARY winding.

Each design allows specific transformer characteristics. See the following table for preferred circuit designs.

  • Neutral wire “N“ or “n”. Percentage of neutral wire current allways refers to nominal current of phase conductor.
  • Please mind:

    • Secundary star circuit allows load on neutral wire.
    • Parallel connection of transformers must comply to following criteria:
      • Nominal voltage and rated frequency
      • Circuit design
      • Short circuit voltages
      • Ratio of rated loads should not extend 3:1