3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).
Transformers
3 Phase Isolating Transformer; Horizontal mounting versionDTL 2.0 - 5.0kVA according to IEC/DIN EN61558-2-4
Typical applications
3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).
Specifications
3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.
Standard switching matrix: Yyn0 (max. typical star load of phase current: approx. 10%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage).Final operation position must allow natural convection through coolant bore. For further information, don´t hesitate …
3 Phase Isolating Transformer; Horizontal mounting versionDTL 5.0 - 35kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).
3 Phase Isolating Transformer, including wall mountable housing – degree of protection IP55DTW 0.1 - 25kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system)
3 Phase Isolating Transformer, base fixed housing – degree of protection IP23DTB 1.6 - 100kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).
1AC PCB Transformer, uncovered version, encapsulated coil, additional mounting optionsPTB 4.4 - 26VA according to IEC/EN61558-2-4/-6
according to IEC/EN61558-2-6 for general applications with double or reinforced insulation and max. output voltage of 50 V, e.g. galvanic isolation for devices according to VDE0805/EN60950 regulations.
1AC Universal Separating TransformerUNT 12 - 500VA IEC/DIN EN61558-2-1 and UL 1446
Separating transformer according to IEC/EN61558-2-1. Power supply of devices or controls without the need of a double or galvanic isolation.
High current transformer up to 65000A (HGV 70 – 300kVA / up to 60kA IEC/DIN EN 61558-2-6)3AC-400V Isolating Transformer, watercooled version High Amperage DC Power Supply
High amperage DC power supply suitable for 3 – 6 VDC output voltages and approx. 80 kA.Input circuit: Thyristor control and primary circuit located taps.
UNI 100 – 2500 VA1 phase control transformer according to IEC/EN61558-2-2
Different PRI primary winding arrangements (serial/ parallel connections) the following mains voltage connections are possible:
200-220-230-250-270-280
330-350-380-390
400-420-430-440-450-470-490
500-550V
Output voltages for UNI…230 types: 115 V or 230 V.
1 Phase Control-/Isolating Transformer, Safety TransformerST 25-2500 VA IEC/DIN EN61558-2-2 /-4 /-6 and UL 1446
Due to the use of high quality insulating materials and special insulation design, ST series can be used as control-, isolating or safety transformer.
Our UL insulation system guarantees global application possibilities.
Inrush currents and short circuit behaviour are optimised for use with motor-circuit switches, especially equipped with primary circuit thermal or magentic switching functions.
Transformers are fully vacuum impregnated.